![]() ![]() Fire Alarm Control Panel IQ8Control C/M Installation Instruction Operation of the Fire Alarm Control Panel IQ8Control is governed by the national version of the operating system software used and the country version programmed in the customer data. ![]() 108 Meaning of the three digit error codes / test mode.115 Functionality for fire alarm control panels. 784385).91 Installer level.96 Diagnostic display.108 Diagnostic display IQ8Control C/M. Fire Alarm Control Panel IQ8Control C/M Master box activation module.87 Technical Data Master box activation module (Part No. 7 Configuration options.8 Special configuration – Swiss option.9 FACP IQ8Control C.10 FACP IQ8Control M.12 Definition of the Primary loop number.17 Central housing.19 Assembly. ![]() Fire Alarm Control Panel IQ8Control C/M Installation Instruction.5 System overview. ![]() This electrically conducting connection between base module and rear panel is essential for correct functional earthing of the FACP IQ8Control C/M.Fire Alarm Control Panel IQ8Control C/M Intended purpose This product must only be used for the applications outlined in the catalogue and the technical description and in combination with external components and systems which have been approved or recommended by Esser by Honeywell. The base module is connected to the rear panel of the cabinet by means of metal spacers and screws. The modular design allows flexible and user-friendlyintegration of several individual modules, which together form one unit. 22: Connection of the rated voltage (230 V AC) and earth connections on the basic module The mains supply must be installed in accordance with local regulations by a qualified technician. Esser Iq8 Control Software The conventional DIBt-approved IQ8 detectors with corresponding. Micro module sMicro module slot 3 The Field device module (if available) must be installed in Slot 1Slot 2 4mm² to PE rail Fig. This internal primary loop number is composed of the control panel number, the slot and the assembly number. Fire Alarm Control Panel IQ8Control C/M Definition of the Primary loop number Individual assemblies of the FACP IQ8Control can be switched on/off with the internal primary loop number through the control panel keyboard or programmed with programming software. 11: Location of the components in a three part housing Mounting plate for master boxes DS 7500 / DS 8800 ®. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
March 2023
Categories |